BDL - Dragon 1.0 (xxBDL4050D) - Scaler Firmware Update

BDL - Dragon 1.0 (xxBDL4050D) - Scaler Firmware Update

Download the Latest Scaler Software

In the root directory of a USB disk (FAT32 formatted) place the PHL_xxBDL4050D.bin files.
Pay attention at the bin file, the file name must match the model number of the monitor you need to upgrade.
(Copy the .bin file named after your model from the below link)

Check if the screen is already running the latest Software version (V1.404)

1. Press in sequence "info, 7, 7"


2. Compare it with the version written in the link above (picture below is an example only, the version may have changed to a later versions)



How to upgrade the Scaler Firmware

1. In the OSD menu, navigate to “Advanced option”, find “Scalar FW Update” and press ok.

2. The display will find the file automatically and start the upgrade

3. When the operation is concluded repower the monitor from the main power (or from the main AC switch on the back of the monitor)
4. Set the burn--in off and perform a factory reset in the factory menu:
      a. Press in a sequence on the remote control below buttons:
            i. Home 1999 back
            ii. Set “burn--in” = off
            iii. Select factory reset
            iv. When finished AC OFF
PLEASE NOTE THAT PERFORMING AN AC REBOOT (PHISYCALLY REMOVE THE ELECTRICAL POWER FROM THE DISPLAY) IS NEEDED TO COMPLETE THE UPGRADE PROCEDURE. NOT COMPLETING THE PROCEDURE MAY CAUSE UNFORSEEN PROBLEMS.


    • Related Articles

    • BDL4650D - Firmware Update Procedure

      Press the following remote control button sequence, INFO, 7, 7 , to check if the Android FW Version is FB01.09. If not, download the latest Android firmware (upgrade.zip) to a PC from ...
    • BDL - Dragon 1.6 (xxBDL4051D) - Scaler Firmware Update

      Download the latest scaler firmware: In the root directory of a USB disk (formatted in FAT32) place the PHL_xxBDL4051D.bin files. Pay attention at the bin file, the file name must match the model number of the monitor you need to upgrade. (Copy the ...
    • BDL - Dragon 1.5 (xxBDL5055P xxBDL5057P) - Scaler Firmware Update

      PHILIPS P Line Scaler Firmware Update In the root directory of a USB disk place the PHL_xxBDL505x.bin files. Pay attention at the bin file, the file name must match the model number of the monitor you need to upgrade. (Copy the .bin file named after ...
    • BDL3050S - Firmware Update Procedure

      Press the following remote control button sequence, INFO, 7, 7 , to check if the Android FW Version is FB02.04. If not, download the latest Android firmware (upgrade.zip) to a PC from https://bit.ly/3UXgJXI (that's three, U for Unicorn, X for X ray, ...
    • BDL4550D - Firmware Update Procedure

      Press the following remote control button sequence, INFO, 7, 7 , to check if the Android FW Version is FB02.20. If not, download the latest Android firmware (upgrade.zip) to a PC from ...