BDL SICP Commonly Used Protocol (V 1.89 onwards)
Command
|
SICP v1.99 Command (HEX)
|
|
|
Power On
|
06 00 00 18 02 1C
|
Power Off
|
06 00 00 18 01 1F
|
Input HDMI
|
09 00 00 AC 0D 00 01 00 A9
|
Input HDMI2
|
09 00 00 AC 06 00 01 00 A2
|
Input HDMI3 | 09 00 00 AC 0F 00 01 00 AB |
Input HDMI4 | 09 00 00 AC 19 00 01 00 BD |
Input VGA
|
09 00 00 AC 05 00 01 00 A1
|
Input DVI-D
|
09 00 00 AC 0E 00 01 00 AA
|
Input USB
|
09 00 00 AC 0C 00 01 00 A8 |
Input Custom | 09 00 00 AC 18 00 01 00 BC |
Volume (speaker and audio out) Up
|
07 00 00 41 01 01 46
|
Volume(speaker and audio out) Down |
07 00 00 41 00 00 46
|
Volume (audio out) Up |
07 00 00 41 02 01 45 |
Volume (audio out) Down | 07 00 00 41 02 00 44 |
Volume mute | 06 00 00 47 01 40 |
Volume unmute | 06 00 00 47 00 41 |
|
|
Volume 0
|
07 00 00 44 00 00 43
|
Volume 10
|
07 00 00 44 0A 0A 43
|
Volume 20
|
07 00 00 44 14 14 43
|
Volume 30
|
07 00 00 44 1E 1E 43
|
Volume 40
|
07 00 00 44 28 28 43
|
Volume 50
|
07 00 00 44 32 32 43
|
Volume 60
|
07 00 00 44 3C 3C 43
|
Most
models only have max Volume 60
|
Volume 70
|
07 00 00 44 46 46 43
|
Volume 80
|
07 00 00 44 50 50 43
|
Volume 90
|
07 00 00 44 5A 5A 43
|
Volume 100
|
07 00 00 44 64 64 43
|
Enable Tiling | 09 00 00 22 01 02 00 00 1C |
Disable Tiling | 09 00 00 22 00 02 00 00 1D |
Your connection need to be set to:
1. Baud Rate : 9600 (except 75BDL3151T - baud rate: 115200)
2. Data bits: 8
3. Parity : None
4. Stop Bit : 1
5. Flow Control : None
If you're connecting via IP (for the models that supports SICP over IP), the default port is TCP port 5000
Latest SICP Protocol Document
Related Articles
BDL3117P Setting Up SICP over IP
Ensure the following settings are set Configuration 1->RS232 routing = LAN->RS232 Network Settings - set accordingly Advanced->Power Mode = Mode 3 BDL SICP Commonly Used Protocol (V 1.89 onwards) ...
BDL3511Q Setting Up SICP over IP
Ensure the following settings are set Configuration 1->RS232 routing = LAN->RS232 Network Settings - set accordingly Advanced->Power Mode = Mode 3 BDL SICP Commonly Used Protocol (V 1.89 onwards) ...
55BDL4002H 75BDL4003H Setting Up SICP over IP
Ensure the following settings are set Configuration 1->RS232 routing = LAN->RS232 Network Settings - set accordingly Advanced->Power Mode = Mode 3 BDL SICP Commonly Used Protocol (V 1.89 onwards) ...
BDL - xxBDL3550Q - Setting up for RS232
RS232 via DB9 cable Set: Home->Config1->RS232-Routing->RS232 Check the Home->Configuration 2->monitor ID is set to the value that will respond to your SICP command RS232 via Network Set: Home->Config1->RS232-Routing->(LAN->RS232) Set Home->Advanced ...
BDL - xxBDL4150D (Himalaya 2.0) - Setting up for RS232
RS232 via DB9 cable Set: Home->Config1->RS232-Routing->RS232 Check the Home->Configuration 2->monitor ID is set to the value that will respond to your SICP command RS232 via Network Set: Home->Config1->RS232-Routing->(LAN->RS232) Set Home->Advanced ...