xxBDL4150D (Himalaya 2.0) Scaler FW Upgrade with USB
Checking the Scaler Software Version if it is already running the latest scaler version V1.145)
press the home button on the RC, select configuration 2, select Monitor Information
Check if the Scaler SW version is V1.145
If it is lower than 1.145, then proceed with performing the SW update.
Downloading the FW File
Download the correct Firmware file from the following link
file names must be the same as the model:
example for model 75BDL4150D the filename must be : 75BDL4150D.bin
Otherwise firmware upgrade won’t work.
Copy the bin file to an USB disk (FAT32)in the root directory and insert the USB stick into the monitor,
see the blue USB marker in below pictures for each model.
Inserting the USB onto the Screen
Enter factory mode by pressing this buttons on the RC in a sequence:Menu, 1, 9, 9, 9, back
Select Main Board update, the monitor will update FW by itself, after successful, the monitor will ask for it to reboot. (power cycle the screen)
Turning Burn in to Off
If Burn in is set to On, turn it off
Enter factory mode by pressing this buttons on the RC in a sequence:Menu+1999+back
Set Burn in to Off (so the color cycling stop)
Checking the Scaler Software Version
Check if firmware has been upgraded: press the home button on the RC, select configuration 2, select
On the right monitor information, the firmware version must match the installed version.
Related Articles
xxBDL4150D (Himalaya 2.0) Android SW Upgrade with USB
Downloading the Android SW File Download the Latest firmware : https://westanonline.sharepoint.com/:f:/s/Support/EtvM545Dd1hWn5_YolF8ZQwBqBdqo9iKLV8VzSlD_Owrnw?e=QxtHkf Copy the update.zip to your usb stick on the root (Do not unzip the file!! ) ...
Philips 75BDL3151T Scaler FW update SOP
Step 1: Prepare for F/W Upgrade 1.1 Prepare a USB disk (must be formatted as FAT 32, allocation block 64kb). 1.2 Download the 3 files from the following link (Latest Scaler for 75BDL3151T): ...
xxHFL3009 xxHFL3010 upgrade_loader.pkg (forced) software update
Warning upgrade_loader.pkg (forced) software update method must be used as a last resort software update method only. autorun.upg (normal) software update is the preferred software update method. ...
xxBDL3010Q USB autoplay
NOTE: USB auto play function is available after TV software ver 1.023; The minimum software version recommended is ver 1.032 USB auto play function with slide show timer feature (to set how long each image is displayed) is available after TV software ...
xxBDL4002H-4003H Firmware Upgrade Procedure via USB
Copy the firmware file corresponding to your model to the USB disk (FAT32) root directory, do NOT rename the file: 55BDL4002H: https://westanonline.sharepoint.com/:u:/s/Support/EewrHpHBXe5LtWRs5BDE2EsBgeBmLEhpYcMlI1XdzV4RsQ?e=AftRoN 75BDL4003H: ...