BDL - xxBDL3550Q - Setting up for RS232

BDL - xxBDL3550Q - Setting up for RS232

RS232 via DB9 cable
Set: Home->Config1->RS232-Routing->RS232
Check the Home->Configuration 2->monitor ID is set to the value that will respond to your SICP command

RS232 via Network
Set: Home->Config1->RS232-Routing->(LAN->RS232)
Set Home->Advanced option->Power Save= Mode 3
Home 1888->Settings->Signage Display-> Network application->SICP network port
     - enable SICP Network port
     - ensure it is set to port 5000
Check the Home->Configuration 2->monitor ID is set to the value that will respond to your SICP command

    • Related Articles

    • 24BDL4151T - Setting up BDL with Browser as source

      BDL – Android – 24BDL4151T - Setting up BDL with Media Player Put the content into the USB in the following directories: philips/video/ -> video philips/photo/ -> photo philips/music/ -> music philips/pdf/ -> pdf Get into The Media Player 1. Put the ...
    • 24BDL4151T - Setting up BDL with Media Player as source

      BDL – Android – 41BDL3051T - Setting up BDL with Media Player Put the content into the USB in the following directories: philips/video/ -> video philips/photo/ -> photo philips/music/ -> music philips/pdf/ -> pdf Get into The Media Player 1. Put the ...
    • 10BDL3051T - Setting up BDL with Browser

      A.    Connect to a network   Enter Admin Menu (press Menu and Vol- button together)   Key in password: 1234 (default)   Select “Network”   Select your chosen interface (Wi-Fi or Ethernet) Select “Enable” If Wi-Fi, select your network SSID from ...
    • Philips BDL Remote Control Not Working

      Philips Signage Remote control not working: [1] Are you using the correct remote control (RC)? Part number: 398GRABDDNEPHT, see picture below: See important note at the end of this document [2] The green led must blink when you press the OK button on ...
    • BDL - xxBDL4150D (Himalaya 2.0) - Setting up for RS232

      RS232 via DB9 cable Set: Home->Config1->RS232-Routing->RS232 Check the Home->Configuration 2->monitor ID is set to the value that will respond to your SICP command RS232 via Network Set: Home->Config1->RS232-Routing->(LAN->RS232) Set Home->Advanced ...