BDL3052E Normal upgrade to Latest Software
Checking the Current SW Version
To check the SW version, press info,7,7. The firmware version is FBxx.xx
Software update (update.zip)
File system=FAT32
Allocation unit size = 64 kilobyte
Download the latest update.zip into USB Drive.
the latest version is FB02.08
Download and put files into the root directory of the USB Drive.
Plug in the USB drive to the screen.
Press the HOME button on the remote controller
Select "Android settings" or press the remote control sequence HOME, 1, 8, 8, 8 to access the Android menu:
Enter the password (default 1,2,3,4)
Navigate to Settings ⇾ Signage Display ⇾ System Updates ⇾ Local update and press OK to initiate the firmware update.
The screen will restart upon completion of the firmware update.
Some USB drives do not get detected by the screen. If the screen fails to recognise the update file, try a different USB drive.
Verify the firmware has been updated by pressing INFO, 7, 7 buttons on the remote.
Related Articles
xxHFL3009 xxHFL3010 upgrade_loader.pkg (forced) software update
Warning upgrade_loader.pkg (forced) software update method must be used as a last resort software update method only. autorun.upg (normal) software update is the preferred software update method. ...
BDL4052E Normal upgrade to Latest Software
Introduction Perform this Update only if the current screen's SW is FB02.09T or higher. To check the SW version, press info,7,7. The firmware version is FBxx.xx If your screen's software is older than FB02.06T, please follow this procedure instead, ...
BDL - Dragon 1.5 (xxBDL5055P xxBDL5057P) - Android Module Software Update
PHILIPS P Line Android Module Software Update Download the latest android firmware: https://westanonline.sharepoint.com/:f:/s/Support/En4_bUolLahbj4BRjTvfbVwB5BGH-xKnlqVwAUyb0ZoGlg?e=3NmvCP In the root directory of a USB disk place ...
BDL4052E Forced upgrade to Latest SW
Introduction The latest FB02.09T FW is a 2 steps operation. 1. NVM Reset (NVM.BIN) - to reorganize the BDL4052E Memory to suit FB02.09T (about 2 mins) 2. Forced update SW (upgrade_loader.pkg) - to update the BDL4052E SW (about 15 mins) Each steps ...
xxHFL4014 upgrade_loader.pkg (forced) software update
Warning upgrade_loader.pkg (forced) software update method must be used as a last resort software update method only. autorun.upg (normal) software update is the preferred software update method. ...