BDL4052E - SICP over IP connection disconnection after a Power On command is sent
Issue: When controlling a BDL4052E using SICP over IP and Power state - Message-Set = On command was sent to the Screen, the TCP/IP Session will get disconnected.
Reconnection can only be established after about 1 minute later.
Solution:
Set Home->Configuration->Logo=Off
The logo is shown during Android reboot, and that's why the current TCP connection is disconnected when screen is being powered on.
#12767