BDL4052E - SICP over IP connection disconnection after a Power On command is sent
Issue: When controlling a BDL4052E using SICP over IP and Power state - Message-Set = On command was sent to the Screen, the TCP/IP Session will get disconnected.
Reconnection can only be established after about 1 minute later.
Solution:
Set Home->Configuration->Logo=Off
The logo is shown during Android reboot, and that's why the current TCP connection is disconnected when screen is being powered on.
#12767
Related Articles
BFL2x14, HFL5x14, HFL6x14 - IP Control via SICP
This article is applicable for: BFL2x14, HFL5x14, HFL6x14. SICP Protocol over IP for the model above is only supported on the TV FW R205.001.099.000 version onwards SICP Protocol over IP to change the source to custom source (like in BDL Models) is ...
BDL SICP Commonly Used Protocol (V 1.89 onwards)
Command SICP v1.99 Command (HEX) Power On 06 00 00 18 02 1C Power Off 06 00 00 18 01 1F Input HDMI 09 00 00 AC 0D 00 01 00 A9 Input HDMI2 09 00 00 AC 06 00 01 00 A2 Input HDMI3 09 00 00 AC 0F 00 01 00 AB Input HDMI4 09 00 00 AC 19 00 01 00 BD Input ...
BDL3117P Setting Up SICP over IP
Ensure the following settings are set Configuration 1->RS232 routing = LAN->RS232 Network Settings - set accordingly Advanced->Power Mode = Mode 3 BDL SICP Commonly Used Protocol (V 1.89 onwards) ...
BDL3511Q Setting Up SICP over IP
Ensure the following settings are set Configuration 1->RS232 routing = LAN->RS232 Network Settings - set accordingly Advanced->Power Mode = Mode 3 BDL SICP Commonly Used Protocol (V 1.89 onwards) ...
55BDL4002H 75BDL4003H Setting Up SICP over IP
Ensure the following settings are set Configuration 1->RS232 routing = LAN->RS232 Network Settings - set accordingly Advanced->Power Mode = Mode 3 BDL SICP Commonly Used Protocol (V 1.89 onwards) ...