Setting Up Custom Input Source App


Go into professional menu by pressing mute, left, right, up, down, ok
Navigate to Advanced->Select TV control app->SICP Control
There was a special app created for installer to be able to specify the custom input source app.

If the option is not there, that means, it needs to be installed

Installing the patch to enable "Custom input source app" option


The easiest way to install the app is to clone in from this BFL with Fusion 2.3.6. app installed
Procedure to clone in is in this link below

Once it's been installed, you should see the option as per the previous instruction above.

Work-Around:


Alternatively if the above is too hard, you can also do this.
Go to Prof Menu
Set Switch On Setting->Feature Settings->Switch On Feature = Apps
Set Switch On Setting->Feature Settings-> Switch On Feature = Apps
Set Switch On Setting->Feature Settings-> Apps = Your App

Turn TV Off 06 00 00 18 01 1F
then
Turn TV back On 06 00 00 18 02 1C

Office Use Only
#11950
    • Related Articles

    • BFL2x14, HFL5x14, HFL6x14 - IP Control via SICP

      This article is applicable for: BFL2x14, HFL5x14, HFL6x14. SICP Protocol over IP for the model above is only supported on the TV FW R205.001.099.000 version onwards SICP Protocol over IP to change the source to custom source (like in BDL Models) is ...
    • BFL2x14 IP Control via SICP

      Please see this article https://support.westan.com.au/portal/en-gb/kb/articles/bfl2x14-hfl5x14-hfl6x14-ip-control-via-sicp
    • BDL4052E - SICP over IP connection disconnection after a Power On command is sent

      Issue: When controlling a BDL4052E using SICP over IP and Power state - Message-Set = On command was sent to the Screen, the TCP/IP Session will get disconnected. Reconnection can only be established after about 1 minute later. Solution: Set ...
    • HFL5x14, HFL6x14 IP Control via SICP

      Please see this article https://support.westan.com.au/portal/en-gb/kb/articles/bfl2x14-hfl5x14-hfl6x14-ip-control-via-sicp
    • BFL2x14 Fusion - How To Change Source

      Configuration Check Press MUTE-LEFT-RIGHT-UP-DOWN-OK (within 2 seconds to Open up the Professional Menu) (see video here: https://support.westan.com.au/portal/kb/articles/22av1905a-mute-left-right-up-down-ok) Navigate to [Input Control]-> [Remote ...